Wasp-barcode WDI4600 2D Product Reference Guide Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Scanners Wasp-barcode WDI4600 2D Product Reference Guide. Wasp Barcode WDI4600 2D Product Reference Guide User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 284
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Product Reference Guide

WDI46001D 2D Digital Scanner USB Product Reference Guide

Page 2

viiiWDI4600NOTES

Page 3 - Table of Contents

Enter/Exit Programming Mode ISSN90WDI4600EAN-13 2D ComponentThis feature enables/disables a requirement that a 2D label component be decoded when a ba

Page 4

EAN 8 (Jan 8) Enter/Exit Programming ModeProduct Reference Guide 91EAN 8 (JAN 8)The following options apply to the EAN 8 (J

Page 5

Enter/Exit Programming Mode EAN 8 (Jan 8)92WDI4600Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.DEFAULT$C8B3B

Page 6

UPC/EAN Global Settings Enter/Exit Programming ModeProduct Reference Guide 93UPC/EAN GLOBAL SETTINGSThis section provides c

Page 7

Enter/Exit Programming Mode UPC/EAN Global Settings94WDI4600UPC/EAN Quiet ZonesThis feature specifies the number of quiet zones for UPC/EAN labels. Qu

Page 8

Add-Ons Enter/Exit Programming ModeProduct Reference Guide 95ADD-ONSContact Customer Support for advanced programming of op

Page 9

Enter/Exit Programming Mode Add-Ons96WDI4600Optional Add-On TimerThis option sets the time the reader will look for an add-on when an add-on fragment

Page 10

$CADOT06(CR)Optional Add-on Timer = 60ms$CADOT07(CR)Optional Add-on Timer = 70msDEFAULT$CADOT0A(CR)Optional Add-on Timer = 100ms$CADOT0C(CR)Optional A

Page 11 - Introduction

$CADOT12(CR)Optional Add-on Timer = 180ms$CADOT14(CR)Optional Add-on Timer = 200ms$CADOT16(CR)Optional Add-on Timer = 220ms$CADOT18(CR)Optional Add-on

Page 12 - Technical Support

Add-Ons Enter/Exit Programming ModeProduct Reference Guide 99Optional GS1-128 Add-On TimerThis option sets the timer expira

Page 13 - Programming the Reader

Product Reference Guide1Chapter 1IntroductionAbout this ManualThis Product Reference Guide (PRG) is provided for users seeking advanced technical info

Page 14

$CADUT06(CR)Optional GS1-128 Add-On Timer = 60ms$CADUT07(CR)Optional GS1-128 Add-On Timer = 70ms$CADUT0A(CR)Optional GS1-128 Add-On Timer = 100ms$CADU

Page 15 - Chapter 2

$CADUT12(CR)Optional GS1-128 Add-On Timer = 180ms$CADUT14(CR)Optional GS1-128 Add-On Timer = 200ms$CADUT16(CR)Optional GS1-128 Add-On Timer = 220ms$CA

Page 16 - RS-232 Serial Connection

Enter/Exit Programming Mode Code 39102WDI4600CODE 39The following options apply to the Code 39 symbology.Code 39 Enable/Disable$CC3EN00(CR)Code 39 = D

Page 17 - USB Connection

Code 39 Enter/Exit Programming ModeProduct Reference Guide 103Code 39 Check Character TransmissionEnable this option to tra

Page 18 - Interface Selection

Enter/Exit Programming Mode Code 39104WDI4600Code 39 Start/Stop Character TransmissionEnable this option to enable/disable transmission of Code 39 sta

Page 19 - 9

Code 39 Enter/Exit Programming ModeProduct Reference Guide 105Code 39 Quiet ZonesThis feature specifies the number of quiet

Page 20 - Setup Interface Selection

Enter/Exit Programming Mode Code 39106WDI4600Code 39 Set Length 1This feature specifies one of the barcode lengths for Code 39 Length Control. Length

Page 21 - 11

Code 39 Enter/Exit Programming ModeProduct Reference Guide 107Code 39 Set Length 2This feature specifies one of the barcode

Page 22 - Software Version Transmission

Enter/Exit Programming Mode Trioptic Code108WDI4600TRIOPTIC CODEThe following options apply to the Trioptic symbology.Trioptic Code Enable/DisableDEFA

Page 23 - Restore Factory Configuration

Code 32 (Ital Pharmaceutical Code) Enter/Exit Programming ModeProduct Reference Guide 109Code 32 Feature Setting Exceptions

Page 24

Introduction References2WDI4600Manual ConventionsThe following conventions are used in this document:The symbols listed below are used in this manual

Page 25 - Configuration Using Barcodes

Enter/Exit Programming Mode Code 39 CIP (French Pharmaceutical)110WDI4600CODE 39 CIP (FRENCH PHARMACEUTICAL)The following options apply to the Code 39

Page 26 - To program features:

Code 39 LaPoste Enter/Exit Programming ModeProduct Reference Guide 111CODE 39 LAPOSTEThe following options apply to the Cod

Page 27 - GLOBAL INTERFACE FEATURES

Enter/Exit Programming Mode Code 128112WDI4600CODE 128The following options apply to the Code 128 symbology.Code 128 Enable/DisableWhen disabled, the

Page 28

Code 128 Enter/Exit Programming ModeProduct Reference Guide 113Code 128 Check Character TransmissionEnable this option to t

Page 29 - ANDSHAKING CONTROL on page 23

Enter/Exit Programming Mode Code 128114WDI4600Code 128 Sub-Code Exchange Transmission Enables/disables the transmission of “Sub-Code Exchange” charact

Page 30 - Baud Rate

Code 128 Enter/Exit Programming ModeProduct Reference Guide 115Code 128 Length ControlThis feature specifies either variabl

Page 31 - Stop Bits

Enter/Exit Programming Mode Code 128116WDI4600Code 128 Set Length 1Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the m

Page 32

Code 128 Enter/Exit Programming ModeProduct Reference Guide 117Code 128 Set Length 2This feature specifies one of the barco

Page 33 - Handshaking Control

Enter/Exit Programming Mode GS1-128118WDI4600GS1-128The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, U

Page 34 - RS-232/USB-COM INTERFACES

Code ISBT 128 Enter/Exit Programming ModeProduct Reference Guide 119CODE ISBT 128The following options apply to the ISBT 12

Page 35 - Beep On ASCII BEL

About the Reader IntroductionProduct Reference Guide 3About the ReaderTypically, units are factory-programmed for the most

Page 36 - Beep On Not on File

Enter/Exit Programming Mode Code ISBT 128120WDI4600ISBT 128 Concatenation ModeSpecifies the concatenation mode between Static and Dynamic.DEFAULT$CI8C

Page 37

Code ISBT 128 Enter/Exit Programming ModeProduct Reference Guide 121ISBT 128 Dynamic Concatenation TimeoutSpecifies the tim

Page 38

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)122WDI4600INTERLEAVED 2 OF 5 (I 2 OF 5)The following options apply to the I 2 of 5 symbology.

Page 39 - Indicate Transmission Failure

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming ModeProduct Reference Guide 123I 2 of 5 Check Character CalculationThi

Page 40

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)124WDI4600I 2 of 5 Check Character TransmissionEnable this option to transmit the check chara

Page 41 - KEYBOARD SETTINGS

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming ModeProduct Reference Guide 125I 2 of 5 Set Length 1This feature speci

Page 42 - Country Mode

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)126WDI4600I 2 of 5 Set Length 2This feature specifies one of the barcode lengths for I 2 of 5

Page 43 - Country Mode (continued)

Interleaved 2 of 5 CIP HR Enter/Exit Programming ModeProduct Reference Guide 127INTERLEAVED 2 OF 5 CIP HRThe following opti

Page 44

Enter/Exit Programming Mode Standard 2 of 5128WDI4600STANDARD 2 OF 5The following options apply to the Standard 2 of 5 symbology.Standard 2 of 5 Enabl

Page 45

Standard 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 129Standard 2 of 5 Check Character TransmissionThis feat

Page 46 - Send Control Characters

Introduction Programming the Reader4WDI4600NOTES

Page 47 - Wedge Quiet Interval

Enter/Exit Programming Mode Standard 2 of 5130WDI4600Standard 2 of 5 Set Length 1This feature specifies one of the barcode lengths for Standard 2 of 5

Page 48 - Caps Lock State

Standard 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 131Standard 2 of 5 Set Length 2This feature specifies on

Page 49 - USB Keyboard Speed

Enter/Exit Programming Mode Industrial 2 of 5132WDI4600INDUSTRIAL 2 OF 5The following options apply to the Industrial 2 of 5 symbology.Industrial 2 of

Page 50 - USB Keyboard Numeric Keypad

Industrial 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 133Industrial 2 of 5 Check Character TransmissionEnabl

Page 51 - NTERFACE OPTIONS on page 42

Enter/Exit Programming Mode Industrial 2 of 5134WDI4600Industrial 2 of 5 Set Length 1This feature specifies one of the barcode lengths for Industrial

Page 52 - Interface Options

Industrial 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 135Industrial 2 of 5 Set Length 2This feature specifie

Page 53 - ABEL ID starting on page 48

Enter/Exit Programming Mode Code IATA136WDI4600CODE IATAThe following options apply to the IATA symbology.IATA Enable/DisableEnables/Disables the abil

Page 54 - Global Prefix/Suffix

Codabar Enter/Exit Programming ModeProduct Reference Guide 137CODABARThe following options apply to the Codabar symbology.C

Page 55

Enter/Exit Programming Mode Codabar138WDI4600Codabar Check Character TransmissionEnable this option to transmit the check character along with Codabar

Page 56

Codabar Enter/Exit Programming ModeProduct Reference Guide 139Codabar Start/Stop Character SetThis option specifies the for

Page 57 - 47

Product Reference Guide5Chapter 2SetupUnpackingCheck carefully to ensure the reader and any accessories ordered are present and undamaged. If any dama

Page 58

Enter/Exit Programming Mode Codabar140WDI4600Codabar Quiet ZonesSpecifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at

Page 59 - Label ID Control

Codabar Enter/Exit Programming ModeProduct Reference Guide 141Codabar Set Length 1This feature specifies one of the barcode

Page 60 - − 1D Symbologies

Enter/Exit Programming Mode Codabar142WDI4600Codabar Set Length 2This feature specifies one of the barcode lengths for Codabar Length ControlCodabar L

Page 61 - 51

ABC Codabar Enter/Exit Programming ModeProduct Reference Guide 143ABC CODABARThe following options apply to the ABC Codabar

Page 62

Enter/Exit Programming Mode ABC Codabar144WDI4600ABC Codabar Dynamic Concatenation TimeoutSpecifies the timeout in 10-millisecond ticks used by the AB

Page 63 - 53

ABC Codabar Enter/Exit Programming ModeProduct Reference Guide 145ABC Codabar Force ConcatenationForces labels starting or

Page 64 - − 2D Symbologies

Enter/Exit Programming Mode Code 11146WDI4600CODE 11The following options apply to the Code 11 symbology.Code 11 Enable/DisableWhen disabled, the read

Page 65 - Case Conversion

Code 11 Enter/Exit Programming ModeProduct Reference Guide 147Code 11 Check Character TransmissionThis feature enables/disa

Page 66

Enter/Exit Programming Mode Code 11148WDI4600Code 11 Set Length 1This feature specifies one of the barcode lengths for Code 11 Length Control. Length

Page 67 - READING PARAMETERS

Code 11 Enter/Exit Programming ModeProduct Reference Guide 149Code 11 Set Length 2This feature specifies one of the barcode

Page 68 - Double Read Timeout

Setup Installing the Interface Cable6WDI4600Installing the Interface CableFor Corded versions, connect the reader cable by inserting the cable into th

Page 69 - 59

Enter/Exit Programming Mode GS1 DataBar™ Omnidirectional150WDI4600GS1 DATABAR™ OMNIDIRECTIONALThe following options apply to the GS1 DataBar™ Omnidire

Page 70 - Good Read: When to Indicate

GS1 DataBar™ Expanded Enter/Exit Programming ModeProduct Reference Guide 151GS1 DataBar™ Omnidirectional 2D ComponentThis f

Page 71 - Good Read Beep Frequency

Enter/Exit Programming Mode GS1 DataBar™ Expanded152WDI4600GS1 DataBar™ Expanded GS1-128 EmulationWhen enabled, GS1 DataBar™ Expanded barcodes will be

Page 72 - Good Read Beep Length

GS1 DataBar™ Expanded Enter/Exit Programming ModeProduct Reference Guide 153GS1 DataBar™ Expanded Length ControlThis featur

Page 73 - Good Read Beep Volume

Enter/Exit Programming Mode GS1 DataBar™ Expanded154WDI4600GS1 DataBar™ Expanded Set Length 1This feature specifies one of the barcode lengths for GS1

Page 74 - Good Read LED Duration

GS1 DataBar™ Expanded Enter/Exit Programming ModeProduct Reference Guide 155GS1 DataBar™ Expanded Set Length 2This feature

Page 75 - SCANNING FEATURES

Enter/Exit Programming Mode GS1 DataBar™ Limited156WDI4600GS1 DATABAR™ LIMITEDThe following options apply to the GS1 DataBar™ Limited (formerly RSS Li

Page 76 - Stand Mode Indication

Code 93 Enter/Exit Programming ModeProduct Reference Guide 157GS1 DataBar™ Limited 2D ComponentThis feature enables/disable

Page 77 - Stand Operation

Enter/Exit Programming Mode Code 93158WDI4600Code 93 Check Character CalculationEnables/disables calculation and verification of an optional Code 93 c

Page 78 - Stand Mode Sensitivity

Code 93 Enter/Exit Programming ModeProduct Reference Guide 159Code 93 Length ControlThis feature specifies either variable

Page 79

Installing the Interface Cable SetupProduct Reference Guide 7Keyboard Wedge ConnectionThe Keyboard Wedge cable has a ‘Y’ co

Page 80 - Motion Still Timeout

Enter/Exit Programming Mode Code 93160WDI4600Code 93 Set Length 1Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the mini

Page 81

Code 93 Enter/Exit Programming ModeProduct Reference Guide 161Code 93 Set Length 2This feature specifies one of the barcode

Page 82 - Aiming Duration Timer

Enter/Exit Programming Mode MSI162WDI4600Code 93 Quiet ZonesEnables/disables quiet zones for Code 93.$CC9LO02(CR)Code 93 Quiet Zones = Quiet Zones on

Page 83 - Mobile Phone Mode

MSI Enter/Exit Programming ModeProduct Reference Guide 163MSI Check Character CalculationEnables/Disables calculation and v

Page 84 - Decode Negative Image

Enter/Exit Programming Mode MSI164WDI4600MSI Length ControlThis feature specifies either variable length decoding or fixed length decoding for the MSI

Page 85 - Corded Stand Mode

MSI Enter/Exit Programming ModeProduct Reference Guide 165MSI Set Length 1This feature specifies one of the barcode lengths

Page 86 - Corded Stand Beep

Enter/Exit Programming Mode MSI166WDI4600MSI Set Length 2This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the max

Page 87 - Multiple Labels per Frame

Plessey Enter/Exit Programming ModeProduct Reference Guide 167PLESSEYThe following options apply to the Plessey symbology.P

Page 88

Enter/Exit Programming Mode Plessey168WDI4600Plessey Check Character TransmissionEnables/disables transmission of an MSI check character.$CPLCT00(CR)P

Page 89 - 1D SYMBOLOGIES

Plessey Enter/Exit Programming ModeProduct Reference Guide 169Plessey Set Length 1This feature specifies one of the barcode

Page 90 - DISABLE ALL SYMBOLOGIES

Setup Interface Selection8WDI4600Figure 5. Other Interface ConnectionsIBM Keyboard Wedge or...Specific cables are required for connection to different

Page 91 - Coupon Control

Enter/Exit Programming Mode Plessey170WDI4600Plessey Set Length 2This feature specifies one of the barcode lengths for Plessey Length Control. Length

Page 92 - UPC-A Enable/Disable

Product Reference Guide1712D SYMBOLOGIES 2D Global Features• 2D Maximum Decoding Time, page 172• 2D Normal/Inverse Symbol Control, page 173• 2D Struct

Page 93 - Expand UPC-A to EAN-13

Enter/Exit Programming Mode 2D Global Features172WDI46002D Maximum Decoding TimeThis feature specifies the maximum amount of time the software will sp

Page 94 - UPC-E Enable/Disable

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 1732D Structured AppendEnables/disables ability of re

Page 95 - UPC-E 2D Component

Enter/Exit Programming Mode Aztec Code174WDI4600Aztec CodeAztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code

Page 96 - Expand UPC-E to UPC-A

Aztec Code Enter/Exit Programming ModeProduct Reference Guide 175Aztec Code Set Length 1Specifies one of the barcode length

Page 97 - GTIN FORMATTING

Enter/Exit Programming Mode Aztec Code176WDI4600Aztec Code Set Length 2This feature specifies one of the barcode lengths for Aztec Code Length Control

Page 98 - EAN 13 Enable/Disable

China Sensible Code Enter/Exit Programming ModeProduct Reference Guide 177China Sensible CodeChina Sensible Code Enable / D

Page 99 - EAN-13 ISBN Conversion

Enter/Exit Programming Mode China Sensible Code178WDI4600China Sensible Code Set Length 1Specifies one of the barcode lengths for China Sensible Code

Page 100 - ISSN Enable/Disable

China Sensible Code Enter/Exit Programming ModeProduct Reference Guide 179China Sensible Code Set Length 2This feature spec

Page 101 - EAN 8 Enable/Disable

Interface Selection SetupProduct Reference Guide 9Table 1. Available InterfacesRS-232 FEATURESRS-232 standard interface

Page 102 - EAN 8 2D Component

Enter/Exit Programming Mode Data Matrix180WDI4600Data MatrixData Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labe

Page 103 - UPC/EAN Price Weight Check

Data Matrix Enter/Exit Programming ModeProduct Reference Guide 181Data Matrix Length ControlThis feature specifies either v

Page 104 - UPC/EAN Quiet Zones

Enter/Exit Programming Mode Data Matrix182WDI4600Data Matrix Set Length 2This feature specifies one of the barcode lengths for Data Matrix Length Cont

Page 105 - Optional Add-ons

Maxicode Enter/Exit Programming ModeProduct Reference Guide 183MaxicodeMaxicode Enable / Disable Enables/disables ability o

Page 106 - Optional Add-On Timer

Enter/Exit Programming Mode Maxicode184WDI4600Maxicode Length ControlThis feature specifies either variable length decoding or fixed length decoding f

Page 107 - 97

Maxicode Enter/Exit Programming ModeProduct Reference Guide 185Maxicode Set Length 2This feature specifies one of the barco

Page 108

Enter/Exit Programming Mode PDF417186WDI4600PDF417PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels.$CP4EN00(

Page 109 - Optional GS1-128 Add-On Timer

PDF417 Enter/Exit Programming ModeProduct Reference Guide 187PDF417 Set Length 1Specifies one of the barcode lengths for PD

Page 110

Enter/Exit Programming Mode PDF417188WDI4600PDF417 Set Length 2This feature specifies one of the barcode lengths for PDF417 Length Control. Length 2 i

Page 111 - 101

Micro PDF417 Enter/Exit Programming ModeProduct Reference Guide 189Micro PDF417Micro PDF417 Enable / Disable Enables/disabl

Page 112 - Code 39 Enable/Disable

Wasp Barcode Technologies1400 10th StreetPlano, Texas USA 75074Tel. 214-547-4100Tel. 214-547-4101©2000-2013 Wasp Barcode Technologies, Inc. (an unpub

Page 113 - 103

KEYBOARD FEATURES

Page 114 - Code 39 Full ASCII

Enter/Exit Programming Mode Micro PDF417190WDI4600Micro PDF417 Length ControlThis feature specifies either variable length decoding or fixed length de

Page 115 - Code 39 Length Control

Micro PDF417 Enter/Exit Programming ModeProduct Reference Guide 191Micro PDF417 Set Length 2This feature specifies one of t

Page 116 - Code 39 Set Length 1

Enter/Exit Programming Mode QR Code192WDI4600QR CodeQR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels$CQREN

Page 117 - Code 39 Set Length 2

QR Code Enter/Exit Programming ModeProduct Reference Guide 193QR Code Set Length 1Specifies one of the barcode lengths for

Page 118 - Code 32 Enable/Disable

Enter/Exit Programming Mode QR Code194WDI4600QR Code Set Length 2This feature specifies one of the barcode lengths for QR Code Length Control. Length

Page 119 - 109

Micro QR Code Enter/Exit Programming ModeProduct Reference Guide 195Micro QR CodeMicro QR Code Enable/DisableEnables/disabl

Page 120 - Code 39 CIP Enable/Disable

Enter/Exit Programming Mode Micro QR Code196WDI4600Micro QR Code Set Length 1Specifies one of the barcode lengths for Micro QR Code Length Control. Le

Page 121 - Code 39 PZN Enable/Disable

Micro QR Code Enter/Exit Programming ModeProduct Reference Guide 197Micro QR Code Set Length 2This feature specifies one of

Page 122 - Expand Code 128 to Code 39

Enter/Exit Programming Mode UCC Composite198WDI4600UCC CompositeUCC Composite Enable / Disable Enables/disables the ability of the reader to decode th

Page 123 - 113

UCC CompositeProduct Reference Guide 199UCC Optional Composite Timer Specifies the amount of time the system will wait for

Page 124 - Code 128 Quiet Zones

KEYBOARD (continued) FEATURESKeyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only key-board

Page 125 - Code 128 Length Control

Postal Code Selection200WDI4600Postal Code SelectionEnables/disables the ability of the scanner to decode labels of a specific postal symbology.• Disa

Page 126 - Code 128 Set Length 1

Postal Code SelectionProduct Reference Guide 201Postal Code Selection (continued)$CPOEN06(CR)Postal Code Selection = Enable

Page 127 - Code 128 Set Length 2

Postal Code Selection202WDI4600NOTES

Page 128 - GS1-128 2D Component

Product Reference Guide203 MOTION FEATURESMOTION AIMING CONTROL on page 203MOTION SENSITIVITY on page 204MOTIONLESS TIMEOUT on page 204Use this chapte

Page 129 - ISBT 128 Force Concatenation

Enter/Exit Programming Mode Motion Features204WDI4600Motion SensitivityDefines discrete set of levels for scanner motion sensitivity when in handheld

Page 130 - ISBT 128 Concatenation Mode

Product Reference Guide205Chapter 4ReferencesThis section contains explanations and examples of selected barcode features. See "Configuration Us

Page 131 - 121

References206WDI4600RS-232 ParametersRS-232 Baud RateBaud rate is the number of bits of data transmitted per second. Set the reader's baud rate t

Page 132 - I 2 of 5 Enable/Disable

RS-232 ParametersProduct Reference Guide 207RS-232/USB COM ParametersIntercharacter DelayThis parameter specifies the inter

Page 133 - 123

References208WDI4600ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader

Page 134 - I 2 of 5 Length Control

RS-232 ParametersProduct Reference Guide 209NAK CharacterThis setting specifies an ASCII character or hex value to be used

Page 135 - I 2 of 5 Set Length 1

Setup Customizing Configuration Settings12WDI4600Customizing Configuration SettingsConfigure Interface SettingsIf after scanning the interface barcode

Page 136 - I 2 of 5 Set Length 2

References210WDI4600ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK character from the host following label

Page 137 - Follett 2 of 5 Enable/Disable

RS-232 ParametersProduct Reference Guide 211ACK NAK Retry CountThis feature specifies the number of times the reader retrie

Page 138 - STANDARD 2 OF 5

References212WDI4600Disable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII characters or any hex value from

Page 139 - 129

RS-232 ParametersProduct Reference Guide 213Enable CharacterSpecifies the value of the RS-232 host command used to enable t

Page 140 - Standard 2 of 5 Set Length 1

References214WDI4600Keyboard InterfaceWedge Quiet IntervalSpecifies the amount of time the reader looks for keyboard activity before it breaks the key

Page 141 - Standard 2 of 5 Set Length 2

Keyboard InterfaceProduct Reference Guide 215Intercharacter DelayThis parameter specifies the intercharacter delay between

Page 142 - INDUSTRIAL 2 OF 5

References216WDI4600Intercode DelaySpecifies the delay between labels transmitted to the host for this interface. The selectable range for this featur

Page 143 - 133

SymbologiesProduct Reference Guide 217SymbologiesSet LengthLength Control allows you to select either variable length decod

Page 144

References218WDI46004. Scan the appropriate two digits from the keypad in Appendix D, Keypad that represent the length setting which was determined in

Page 145 - 135

Data EditingProduct Reference Guide 219Please Keep In Mind...• Modifying a message string is not a mandatory requirement. D

Page 146 - IATA Enable/Disable

Customizing Configuration Settings SetupProduct Reference Guide 13Resetting the Product Configuration to DefaultsRestore Cu

Page 147 - Codabar Enable/Disable

References220WDI4600Global AIM IDThis feature enables/disables addition of AIM IDs for all symbology types.AIM label identifiers (as opposed to custom

Page 148

Data EditingProduct Reference Guide 221Label IDA Label ID is a customizable code of up to three ASCII characters (each can

Page 149 - 139

References222WDI4600DATABAR 14 COMPOSITER4 523400 c 523400DATABAR EXPANDEDRX 525800 t 740000DATABAR EXPANDED COMPOSITERX 525800 d 525800DATABAR LIMITE

Page 150 - Codabar Length Control

Data EditingProduct Reference Guide 223MSI@ 400000 Z 5A0000PDF417P 500000 r 720000PLESSEYa 610000 a 610000POSTAL AUSTRALIAN

Page 151 - Codabar Set Length 1

References224WDI4600Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a single symbology:1. Go to page 49 and scan the

Page 152 - Codabar Set Length 2

Data EditingProduct Reference Guide 225Table 36STEP ACTION EXAMPLES1. Scan the ENTER/EXIT barcode(Scanner enters Programmin

Page 153 - ABC Codabar Enable/Disable

References226WDI4600Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in

Page 154 - Concatenation Mode

Reading ParametersProduct Reference Guide 227Reading ParametersGood Read LED DurationThis feature specifies the amount of t

Page 155 - 145

References228WDI4600Scanning FeaturesScan ModeThis mode is associated with typical handheld reader operation. Selects the scan operating mode for the

Page 156 - Code 11 Enable/Disable

Scanning FeaturesProduct Reference Guide 229Stand Mode Off TimeThis feature specifies the amount of time reader illuminatio

Page 157 - Code 11 Length Control

Setup Customizing Configuration Settings14WDI4600NOTES

Page 158 - Code 11 Set Length 1

References230WDI4600Scanning Active TimeThis setting specifies the amount of time that the reader stays in scan ON state once the state is entered. Th

Page 159 - Code 11 Set Length 2

Scanning FeaturesProduct Reference Guide 231Aiming Duration TimeSpecifies the frame of time the aiming pointer remains on a

Page 160 - GS1 DATABAR™ OMNIDIRECTIONAL

References232WDI4600Flash On TimeThis feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 mi

Page 161 - GS1 DATABAR™ EXPANDED

Scanning FeaturesProduct Reference Guide 233Flash Off TimeThis feature specifies the OFF time for the indicator LED while i

Page 162

References234WDI4600Multiple Labels Ordering by Code SymbologyThis feature Specifies the transmission ordering by symbology type, when Multiple Labels

Page 163 - 153

Scanning FeaturesProduct Reference Guide 235Table 44HexValue Symbology IDHexValue Symbology ID00Don't care2CGTIN501UPC

Page 164

References236WDI4600Motion FeaturesMotionless TimeoutThis setting specifies the amount of time that the reader takes to assume that it is in a motionl

Page 165 - 155

Product Reference Guide237Appendix ATechnical SpecificationsTable 46 contains Physical and Performance Characteristics, User Environment and Regulator

Page 166 - GS1 DATABAR™ LIMITED

Technical Specifications238WDI4600Depth of Field (Typical) a Symbology Standard Range (SR) ModelsCode 395mil: 1.6” -7.5” (4.0 -19cm) 10mil: 0.4” - 11.

Page 167 - Code 93 Enable/Disable

Technical SpecificationsProduct Reference Guide 239Decode Capability1D BarcodesUPC/EAN/JAN (A, E, 13, 8); UPC/EAN/JAN (incl

Page 168 - Enable Check C

Product Reference Guide15Chapter 3Configuration Using BarcodesThis and following sections provide programming barcodes to configure your reader by cha

Page 169 - Code 93 Length Control

Item DescriptionUser Environment WDI4600Operating Temperature32° to 131° F (0° to 55° C)Charging TemperatureN/AStorage Temperature-4° to 158° F (-20°

Page 170 - Code 93 Set Length 1

Technical SpecificationsProduct Reference Guide 241Imager LabelingSample labels are shown for illustrative purposes only. P

Page 171 - Code 93 Set Length 2

Technical Specifications242WDI4600Standard Cable PinoutsFigure 10, and Table 47 provide standard pinout information for the interface cable.Figure 10

Page 172 - MSI Enable/Disable

Technical SpecificationsProduct Reference Guide 243LED and Beeper IndicationsThe reader’s beeper sounds and its LED illumin

Page 173 - 163

Technical Specifications244WDI4600Table 49Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.Label Program

Page 174 - MSI Length Control

Product Reference Guide245Appendix BStandard DefaultsThe most common configuration settings are listed in the “Default” column of the table below. Pag

Page 175 - MSI Set Length 1

Standard Defaults246WDI4600Disable Character‘D’ 30Enable Character‘E’ 30KEYBOARD WEDGECountry ModeU.S. Keyboard 32Send Control Characters00 36Wedge Qu

Page 176 - MSI Set Length 2

Standard DefaultsProduct Reference Guide 247Good Read Beep Length80 ms 62Good Read Beep VolumeHigh 63Good Read LED Duration

Page 177 - Plessey Enable/Disable

Standard Defaults248WDI4600CODE SELECTION - 1D SYMBOLOGIESCode EAN/UPCCoupon ControlEnable only UPCAcoupon decoding81UPC-AUPC-A Enable/DisableEnable 8

Page 178 - Plessey Length Control

Standard DefaultsProduct Reference Guide 249EAN 8 Check Character TransmissionSend91Expand EAN 8 to EAN 13Disable92EAN 8 2D

Page 179 - Plessey Set Length 1

Enter/Exit Programming Mode16WDI4600To program features:1. Scan the ENTER/EXIT PROGRAMMING barcode, available at the top of each pro-gramming page, wh

Page 180 - Plessey Set Length 2

Standard Defaults250WDI4600Code 39 Danish PPT Enable/DisableDisable 110Code 39 LaPoste Enable/DisableDisable 111Code 39 PZN Enable/DisableDisable 111C

Page 181 - 2D SYMBOLOGIES

Standard DefaultsProduct Reference Guide 251Interleaved 2 of 5 CIP HR Enable/DisableDisable 127Follett 2 of 5Follett 2 of 5

Page 182 - 2D Maximum Decoding Time

Standard Defaults252WDI4600Codabar Set Length 250 142ABC CodabarDisable 143ABC CodabarABC Codabar Enable/DisableDisable 143ABC Codabar Concatenation M

Page 183 - 2D Structured Append

Standard DefaultsProduct Reference Guide 253GS1 DataBar™ Limited 2D Component2D component not required157Code 93Code 93 Ena

Page 184 - Aztec Code

Standard Defaults254WDI4600Aztec Code Length ControlVariable 174Aztec Code Set Length 11 175China Sensible Code Enable / DisableDisable 177China Sensi

Page 185 - Aztec Code Set Length 1

Standard DefaultsProduct Reference Guide 255Micro QR Code Enable/DisableDisable 195Micro QR Code Length ControlVariable 195

Page 186 - Aztec Code Set Length 2

Standard Defaults256WDI4600NOTES

Page 187 - China Sensible Code

Product Reference Guide257Appendix CSample BarcodesThe sample barcodes in this appendix are typical representations for their symbology types.1D Barco

Page 188 - Set Length 1

Sample Barcodes258WDI4600Sample Barcodes (continued) Code 32Codabar13579 Code 93 Code 11123456789

Page 189 - 179

Sample BarcodesProduct Reference Guide 259GS1 DataBar™ (RSS)GS1 DataBar™ Expanded Stacked1029384756019283746501928374602947

Page 190 - Data Matrix

Global Interface Features Enter/Exit Programming ModeProduct Reference Guide 17GLOBAL INTERFACE FEATURESThe following inter

Page 191

Sample Barcodes260WDI46002D BarcodesAztec DatamatrixChina Sensible Code MaxiCodePDF 417ABCabcMicro PDF 417

Page 192 - Data Matrix Set Length 2

Product Reference Guide261Appendix DKeypadUse the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.01234

Page 193 - Maxicode

Keypad262WDI4600ABCDEF

Page 194

Product Reference Guide263Appendix EScancode TablesControl Character EmulationControl character emulation selects from different scancode tables as li

Page 195 - Maxicode Set Length 2

264WDI4600Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLETable 51. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x3 x4 x

Page 196 - PDF417 Length Control

Product Reference Guide 265Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE (continued)Table 52. Scancode Set When Control Character

Page 197 - PDF417 Set Length 1

266WDI4600Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 53. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x3 x4 x5 X6 x

Page 198 - PDF417 Set Length 2

Product Reference Guide 267Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode (continued)Table 54. Scancode Set When Control Character is 02

Page 199 - Micro PDF417

268WDI4600Digital InterfaceTable 55. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC+@SOHC(S)

Page 200 - Micro PDF417 Set Length 1

Product Reference Guide 269IBM31xx 102-keyTable 57. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

Page 201 - Micro PDF417 Set Length 2

Enter/Exit Programming Mode Global Interface Features18WDI4600NOTES

Page 202 - QR Code Length Control

270WDI4600IBM XTTable 59. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC+@SOHC(S)+ASTXC(S)+

Page 203

Scancode TablesProduct Reference Guide 271Microsoft Windows Codepage 1252Windows-1252 is a character encoding of the Latin

Page 204 - Set Length 2

Scancode Tables272WDI4600NOTES

Page 205 - Micro QR Code

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE

Page 206

Wasp Barcode Technologies1400 10th StreetPlano, Texas USA 75074www.waspbarcode.com820033790 (Rev. C) December 2013

Page 207

Product Reference Guide19RS-232 INTERFACEBAUD RATE on page 20DATA BITS on page 21STOP BITS on page 21PARITY on page 22HANDSHAKING CONTROL on page 23Us

Page 208 - UCC Composite

Product Reference GuideiTable of ContentsINTRODUCTION ...

Page 209 - UCC Optional Composite Timer

Enter/Exit Programming Mode RS-232 Interface20WDI4600Baud RateSee page 206 for information on this feature.$CR2BA00(CR)Baud Rate = 1200$CR2BA01(CR)Bau

Page 210 - Postal Code Selection

RS-232 Interface Enter/Exit Programming ModeProduct Reference Guide 21Data BitsThis parameter allows the reader to interfac

Page 211 - Postnet BB Control

Enter/Exit Programming Mode RS-232 Interface22WDI4600ParityThis feature specifies parity required for sending and receiving data. Select the parity ty

Page 212

RS-232 Interface Enter/Exit Programming ModeProduct Reference Guide 23Handshaking ControlDEFAULT$CR2HC00(CR)Handshaking Con

Page 213 - Motion Aiming Control

Product Reference Guide24RS-232/USB-COM INTERFACESINTERCHARACTER DELAY on page 25BEEP ON ASCII BEL on page 25BEEP ON NOT ON FILE on page 26ACK NAK OPT

Page 214 - Motionless Timeout

RS-232/USB-Com Interfaces Enter/Exit Programming ModeProduct Reference Guide 25Intercharacter DelayThis parameter specifies

Page 215 - Chapter 4

Enter/Exit Programming Mode RS-232/USB-Com Interfaces26WDI4600Beep On Not on FileThis option enables/disables the action of the reader to sound a thre

Page 216 - RS-232 Parameters

RS-232/USB-Com Interfaces Enter/Exit Programming ModeProduct Reference Guide 27ACK CharacterThis setting specifies an ASCII

Page 217 - RS-232/USB COM Parameters

Enter/Exit Programming Mode RS-232/USB-Com Interfaces28WDI4600ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an AC

Page 218 - ACK Character

RS-232/USB-Com Interfaces Enter/Exit Programming ModeProduct Reference Guide 29ACK NAK Error HandlingThis feature specifies

Page 219 - NAK Character

iiWDI4600USB Keyboard Speed ...

Page 220 - ACK NAK Timeout Value

Enter/Exit Programming Mode RS-232/USB-Com Interfaces30WDI4600Disable CharacterSpecifies the value of the RS-232 host command used to disable the read

Page 221 - ACK NAK Retry Count

Product Reference Guide31KEYBOARD SETTINGSCOUNTRY MODE on page 32SEND CONTROL CHARACTERS on page 36WEDGE QUIET INTERVAL on page 37INTERCODE DELAY on p

Page 222 - Disable Character

Enter/Exit Programming Mode Keyboard Settings32WDI4600Country ModeThis feature specifies the country/language supported by the keyboard. Several langu

Page 223 - Enable Character

Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 33Country Mode (continued)$CKBCO04(CR)Country Mode = F

Page 224 - Keyboard Interface

Enter/Exit Programming Mode Keyboard Settings34WDI4600Country Mode (continued)$CKBCO14(CR)Country Mode = LithuanianSupports only the interfaces listed

Page 225 - Intercharacter Delay

Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 35Country Mode (continued)$CKBCO09(CR)Country Mode = S

Page 226 - Intercode Delay

Enter/Exit Programming Mode Keyboard Settings36WDI4600Send Control CharactersThis feature specifies how the reader transmits ASCII control characters

Page 227 - Symbologies

Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 37Wedge Quiet IntervalSpecifies amount of time to look

Page 228 - Data Editing

Enter/Exit Programming Mode Keyboard Settings38WDI4600Caps Lock StateThis option specifies the format in which the reader sends character data. This d

Page 229 - 00 - 20 Characters (ASCII)

Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 39USB Keyboard SpeedThis option specifies the USB poll

Page 230 - Global AIM ID

Product Reference GuideiiiUPC-A 2D Component ...

Page 231 - Label ID

$CKBSP07(CR)USB Keyboard Speed = 7ms$CKBSP08(CR)USB Keyboard Speed = 8ms$CKBSP09(CR)USB Keyboard Speed = 9ms$CKBSP0A(CR)USB Keyboard Speed = 10msEnter

Page 232

Product Reference Guide41USB-OEM INTERFACEUSB-OEM DEVICE USAGE on page 42INTERFACE OPTIONS on page 42Feature settings for USB interfaces differ depend

Page 233 - 223

Enter/Exit Programming Mode USB-OEM Interface42WDI4600USB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of two di

Page 234

Product Reference Guide43DATA FORMATGLOBAL PREFIX/SUFFIX starting on page 44GLOBAL AIM ID starting on page 45LABEL ID starting on page 48•Label ID: Pr

Page 235 - 225

Enter/Exit Programming Mode Data Format44WDI4600Global Prefix/SuffixThis option sets up to 20 characters each from the set of ASCII characters or any

Page 236 - Character Conversion

Data Format Enter/Exit Programming ModeProduct Reference Guide 45Global AIM IDThis feature enables/disables addition of AIM

Page 237 - Reading Parameters

Enter/Exit Programming Mode Data Format46WDI4600DATABAR EXPANDED COMPOSITE e 65DATABAR LIMITED e 65DATABAR LIMITED COMPOSITE e 65DATA MATRIX d 64EAN12

Page 238 - Scanning Features

Data Format Enter/Exit Programming ModeProduct Reference Guide 47Set AIM ID Individually for GS1-128This feature configures

Page 239 - Stand Mode Off Time

Enter/Exit Programming Mode Data Format48WDI4600Label IDA Label ID is a customizable code of up to three ASCII characters (convert to Hex using the AS

Page 240 - Scanning Active Time

Data Format Enter/Exit Programming ModeProduct Reference Guide 49Individually Set Label IDThis feature configures a Label I

Page 241 - Aiming Duration Time

ivWDI4600Code 128 Set Length 1 ...

Page 242 - Flash On Time

Enter/Exit Programming Mode Data Format50WDI4600Label ID Symbology Selection − 1D Symbologies This option selects the symbology for which a Label ID i

Page 243 - Flash Off Time

Data Format Enter/Exit Programming ModeProduct Reference Guide 51Label ID Symbology Selection − 1D Symbologies (continued)$

Page 244

Enter/Exit Programming Mode Data Format52WDI4600Label ID Symbology Selection − 1D Symbologies (continued)$CXBIDSet GS1 DataBar Expanded Label ID Chara

Page 245 - 235

Data Format Enter/Exit Programming ModeProduct Reference Guide 53Label ID Symbology Selection − 1D Symbologies (continued)$

Page 246 - Motion Features

$CAZIDSet Aztec Label ID Character(s)$CMXIDSet Maxicode Label ID Character(s)$CCSIDSet China Sensible Label ID Character(s)$CP4IDSet PDF 417 Label ID

Page 247 - Technical Specifications

Data Format Enter/Exit Programming ModeProduct Reference Guide 55Advanced Formatting: User Label EditAdvanced formatting is

Page 248

Enter/Exit Programming Mode Data Format56WDI4600Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 ch

Page 249 - 239

Product Reference Guide57 READING PARAMETERS DOUBLE READ TIMEOUT starting on page 58LED AND BEEPER INDICATORS starting on page 60•Power On Alert•Good

Page 250

Enter/Exit Programming Mode Reading Parameters58WDI4600Double Read TimeoutDouble Read Timeout prevents a double read of the same label by setting the

Page 251 - Scanner Regulatory Label

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 59Double Read Timeout (continued)$CSNDR50(CR)Double R

Page 252 - Standard Cable Pinouts

Product Reference GuidevGS1 DataBar™ Omnidirectional Enable/Disable ...

Page 253 - LED and Beeper Indications

Enter/Exit Programming Mode Reading Parameters60WDI4600LED AND BEEPER INDICATORSPower On AlertDisables or enables the indication (from the Beeper) tha

Page 254 - Error Codes

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 61Good Read Beep TypeSpecifies whether the good read

Page 255 - Standard Defaults

Enter/Exit Programming Mode Reading Parameters62WDI4600Good Read Beep Length

Page 256

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 63Good Read Beep VolumeSelects the beeper volume (lou

Page 257 - 247

Enter/Exit Programming Mode Reading Parameters64WDI4600Good Read LED DurationThis feature specifies the amount of time that the Good Read LED remains

Page 258

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 65SCANNING FEATURESScan ModeSelects the reader’s scan

Page 259 - 249

Enter/Exit Programming Mode Reading Parameters66WDI4600Stand Mode IndicationThis operation is useful for indicating when the reader is in Stand Mode.

Page 260

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 67Stand OperationSpecifies the behavior of the reader

Page 261 - 251

Enter/Exit Programming Mode Reading Parameters68WDI4600Pick ModeSpecifies the ability of the reader to decode labels only when they are close to the c

Page 262

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 69Stand Mode Illumination Off TimeSpecifies the amoun

Page 263 - 253

viWDI4600Maxicode Set Length 2 ...

Page 264

Enter/Exit Programming Mode Reading Parameters70WDI4600Stand Illumination ControlControls the illumination status while the reading mode is stand mode

Page 265 - 255

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 71Flash On TimeThis feature specifies the ON time for

Page 266

Enter/Exit Programming Mode Reading Parameters72WDI4600Aiming PointerEnables/disables the aiming pointer for all symbologies.$CTAAP00(CR)Aiming Pointe

Page 267 - Sample Barcodes

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 73Green Spot DurationSpecifies the duration of the go

Page 268 - Sample Barcodes (continued)

Enter/Exit Programming Mode Reading Parameters74WDI4600Partial Label Reading ControlEnable/Disable to ignore partial labels to be read within the boun

Page 269 - GS1 DataBar™-14

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 75CORDED ONLY FEATURESCorded Stand ModeSets the Stan

Page 270 -

Enter/Exit Programming Mode Reading Parameters76WDI4600Corded Stand BeepEnables/Disables the beep that indicates when Corded Stand position is detecte

Page 271 - Appendix D

Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 77 MULTIPLE LABEL READINGIn standard (default) mode,

Page 272

Enter/Exit Programming Mode Reading Parameters78WDI4600Multiple Labels Ordering by Code SymbologyThis feature allows you to specify the order multiple

Page 273 - Scancode Tables

Product Reference Guide791D SYMBOLOGIES1D Code SelectionThe reader supports the following 1D symbologies (barcode types). See "2D Symbologies&quo

Page 274

Product Reference GuideviiLED and Beeper Indications ...

Page 275 - Product Reference Guide 265

Enter/Exit Programming Mode Disable All Symbologies80WDI46004. Complete the programming sequence by scanning the ENTER/EXIT PROGRAM-MING barcode to ex

Page 276

Code EAN/UPC Enter/Exit Programming ModeProduct Reference Guide 81CODE EAN/UPCCoupon ControlThis feature is used to control

Page 277 - Product Reference Guide 267

Enter/Exit Programming Mode Code EAN/UPC82WDI4600UPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled, the reader

Page 278 - Digital Interface

Code EAN/UPC Enter/Exit Programming ModeProduct Reference Guide 83Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 da

Page 279 - IBM31xx 102-key

Enter/Exit Programming Mode UPC-E84WDI4600UPC-A 2D ComponentThis feature enables/disables a requirement that a 2D label component be decoded when a ba

Page 280

UPC-E Enter/Exit Programming ModeProduct Reference Guide 85UPC-E Check Character TransmissionEnable this option to transmit

Page 281 - 271

Enter/Exit Programming Mode UPC-E86WDI4600Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the

Page 282

GTIN Formatting Enter/Exit Programming ModeProduct Reference Guide 87UPC-E Number System Character TransmissionThis feature

Page 283 - ASCII Chart

Enter/Exit Programming Mode EAN 13 (Jan 13)88WDI4600EAN 13 (JAN 13)The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable/DisableW

Page 284 - Plano, Texas USA 75074

EAN 13 (Jan 13) Enter/Exit Programming ModeProduct Reference Guide 89EAN-13 Flag 1 CharacterEnables/disables transmission o

Commentaires sur ces manuels

Pas de commentaire