WDI46001D 2D Digital Scanner USB Product Reference Guide
viiiWDI4600NOTES
Enter/Exit Programming Mode ISSN90WDI4600EAN-13 2D ComponentThis feature enables/disables a requirement that a 2D label component be decoded when a ba
EAN 8 (Jan 8) Enter/Exit Programming ModeProduct Reference Guide 91EAN 8 (JAN 8)The following options apply to the EAN 8 (J
Enter/Exit Programming Mode EAN 8 (Jan 8)92WDI4600Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.DEFAULT$C8B3B
UPC/EAN Global Settings Enter/Exit Programming ModeProduct Reference Guide 93UPC/EAN GLOBAL SETTINGSThis section provides c
Enter/Exit Programming Mode UPC/EAN Global Settings94WDI4600UPC/EAN Quiet ZonesThis feature specifies the number of quiet zones for UPC/EAN labels. Qu
Add-Ons Enter/Exit Programming ModeProduct Reference Guide 95ADD-ONSContact Customer Support for advanced programming of op
Enter/Exit Programming Mode Add-Ons96WDI4600Optional Add-On TimerThis option sets the time the reader will look for an add-on when an add-on fragment
$CADOT06(CR)Optional Add-on Timer = 60ms$CADOT07(CR)Optional Add-on Timer = 70msDEFAULT$CADOT0A(CR)Optional Add-on Timer = 100ms$CADOT0C(CR)Optional A
$CADOT12(CR)Optional Add-on Timer = 180ms$CADOT14(CR)Optional Add-on Timer = 200ms$CADOT16(CR)Optional Add-on Timer = 220ms$CADOT18(CR)Optional Add-on
Add-Ons Enter/Exit Programming ModeProduct Reference Guide 99Optional GS1-128 Add-On TimerThis option sets the timer expira
Product Reference Guide1Chapter 1IntroductionAbout this ManualThis Product Reference Guide (PRG) is provided for users seeking advanced technical info
$CADUT06(CR)Optional GS1-128 Add-On Timer = 60ms$CADUT07(CR)Optional GS1-128 Add-On Timer = 70ms$CADUT0A(CR)Optional GS1-128 Add-On Timer = 100ms$CADU
$CADUT12(CR)Optional GS1-128 Add-On Timer = 180ms$CADUT14(CR)Optional GS1-128 Add-On Timer = 200ms$CADUT16(CR)Optional GS1-128 Add-On Timer = 220ms$CA
Enter/Exit Programming Mode Code 39102WDI4600CODE 39The following options apply to the Code 39 symbology.Code 39 Enable/Disable$CC3EN00(CR)Code 39 = D
Code 39 Enter/Exit Programming ModeProduct Reference Guide 103Code 39 Check Character TransmissionEnable this option to tra
Enter/Exit Programming Mode Code 39104WDI4600Code 39 Start/Stop Character TransmissionEnable this option to enable/disable transmission of Code 39 sta
Code 39 Enter/Exit Programming ModeProduct Reference Guide 105Code 39 Quiet ZonesThis feature specifies the number of quiet
Enter/Exit Programming Mode Code 39106WDI4600Code 39 Set Length 1This feature specifies one of the barcode lengths for Code 39 Length Control. Length
Code 39 Enter/Exit Programming ModeProduct Reference Guide 107Code 39 Set Length 2This feature specifies one of the barcode
Enter/Exit Programming Mode Trioptic Code108WDI4600TRIOPTIC CODEThe following options apply to the Trioptic symbology.Trioptic Code Enable/DisableDEFA
Code 32 (Ital Pharmaceutical Code) Enter/Exit Programming ModeProduct Reference Guide 109Code 32 Feature Setting Exceptions
Introduction References2WDI4600Manual ConventionsThe following conventions are used in this document:The symbols listed below are used in this manual
Enter/Exit Programming Mode Code 39 CIP (French Pharmaceutical)110WDI4600CODE 39 CIP (FRENCH PHARMACEUTICAL)The following options apply to the Code 39
Code 39 LaPoste Enter/Exit Programming ModeProduct Reference Guide 111CODE 39 LAPOSTEThe following options apply to the Cod
Enter/Exit Programming Mode Code 128112WDI4600CODE 128The following options apply to the Code 128 symbology.Code 128 Enable/DisableWhen disabled, the
Code 128 Enter/Exit Programming ModeProduct Reference Guide 113Code 128 Check Character TransmissionEnable this option to t
Enter/Exit Programming Mode Code 128114WDI4600Code 128 Sub-Code Exchange Transmission Enables/disables the transmission of “Sub-Code Exchange” charact
Code 128 Enter/Exit Programming ModeProduct Reference Guide 115Code 128 Length ControlThis feature specifies either variabl
Enter/Exit Programming Mode Code 128116WDI4600Code 128 Set Length 1Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the m
Code 128 Enter/Exit Programming ModeProduct Reference Guide 117Code 128 Set Length 2This feature specifies one of the barco
Enter/Exit Programming Mode GS1-128118WDI4600GS1-128The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, U
Code ISBT 128 Enter/Exit Programming ModeProduct Reference Guide 119CODE ISBT 128The following options apply to the ISBT 12
About the Reader IntroductionProduct Reference Guide 3About the ReaderTypically, units are factory-programmed for the most
Enter/Exit Programming Mode Code ISBT 128120WDI4600ISBT 128 Concatenation ModeSpecifies the concatenation mode between Static and Dynamic.DEFAULT$CI8C
Code ISBT 128 Enter/Exit Programming ModeProduct Reference Guide 121ISBT 128 Dynamic Concatenation TimeoutSpecifies the tim
Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)122WDI4600INTERLEAVED 2 OF 5 (I 2 OF 5)The following options apply to the I 2 of 5 symbology.
Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming ModeProduct Reference Guide 123I 2 of 5 Check Character CalculationThi
Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)124WDI4600I 2 of 5 Check Character TransmissionEnable this option to transmit the check chara
Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming ModeProduct Reference Guide 125I 2 of 5 Set Length 1This feature speci
Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)126WDI4600I 2 of 5 Set Length 2This feature specifies one of the barcode lengths for I 2 of 5
Interleaved 2 of 5 CIP HR Enter/Exit Programming ModeProduct Reference Guide 127INTERLEAVED 2 OF 5 CIP HRThe following opti
Enter/Exit Programming Mode Standard 2 of 5128WDI4600STANDARD 2 OF 5The following options apply to the Standard 2 of 5 symbology.Standard 2 of 5 Enabl
Standard 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 129Standard 2 of 5 Check Character TransmissionThis feat
Introduction Programming the Reader4WDI4600NOTES
Enter/Exit Programming Mode Standard 2 of 5130WDI4600Standard 2 of 5 Set Length 1This feature specifies one of the barcode lengths for Standard 2 of 5
Standard 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 131Standard 2 of 5 Set Length 2This feature specifies on
Enter/Exit Programming Mode Industrial 2 of 5132WDI4600INDUSTRIAL 2 OF 5The following options apply to the Industrial 2 of 5 symbology.Industrial 2 of
Industrial 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 133Industrial 2 of 5 Check Character TransmissionEnabl
Enter/Exit Programming Mode Industrial 2 of 5134WDI4600Industrial 2 of 5 Set Length 1This feature specifies one of the barcode lengths for Industrial
Industrial 2 of 5 Enter/Exit Programming ModeProduct Reference Guide 135Industrial 2 of 5 Set Length 2This feature specifie
Enter/Exit Programming Mode Code IATA136WDI4600CODE IATAThe following options apply to the IATA symbology.IATA Enable/DisableEnables/Disables the abil
Codabar Enter/Exit Programming ModeProduct Reference Guide 137CODABARThe following options apply to the Codabar symbology.C
Enter/Exit Programming Mode Codabar138WDI4600Codabar Check Character TransmissionEnable this option to transmit the check character along with Codabar
Codabar Enter/Exit Programming ModeProduct Reference Guide 139Codabar Start/Stop Character SetThis option specifies the for
Product Reference Guide5Chapter 2SetupUnpackingCheck carefully to ensure the reader and any accessories ordered are present and undamaged. If any dama
Enter/Exit Programming Mode Codabar140WDI4600Codabar Quiet ZonesSpecifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at
Codabar Enter/Exit Programming ModeProduct Reference Guide 141Codabar Set Length 1This feature specifies one of the barcode
Enter/Exit Programming Mode Codabar142WDI4600Codabar Set Length 2This feature specifies one of the barcode lengths for Codabar Length ControlCodabar L
ABC Codabar Enter/Exit Programming ModeProduct Reference Guide 143ABC CODABARThe following options apply to the ABC Codabar
Enter/Exit Programming Mode ABC Codabar144WDI4600ABC Codabar Dynamic Concatenation TimeoutSpecifies the timeout in 10-millisecond ticks used by the AB
ABC Codabar Enter/Exit Programming ModeProduct Reference Guide 145ABC Codabar Force ConcatenationForces labels starting or
Enter/Exit Programming Mode Code 11146WDI4600CODE 11The following options apply to the Code 11 symbology.Code 11 Enable/DisableWhen disabled, the read
Code 11 Enter/Exit Programming ModeProduct Reference Guide 147Code 11 Check Character TransmissionThis feature enables/disa
Enter/Exit Programming Mode Code 11148WDI4600Code 11 Set Length 1This feature specifies one of the barcode lengths for Code 11 Length Control. Length
Code 11 Enter/Exit Programming ModeProduct Reference Guide 149Code 11 Set Length 2This feature specifies one of the barcode
Setup Installing the Interface Cable6WDI4600Installing the Interface CableFor Corded versions, connect the reader cable by inserting the cable into th
Enter/Exit Programming Mode GS1 DataBar™ Omnidirectional150WDI4600GS1 DATABAR™ OMNIDIRECTIONALThe following options apply to the GS1 DataBar™ Omnidire
GS1 DataBar™ Expanded Enter/Exit Programming ModeProduct Reference Guide 151GS1 DataBar™ Omnidirectional 2D ComponentThis f
Enter/Exit Programming Mode GS1 DataBar™ Expanded152WDI4600GS1 DataBar™ Expanded GS1-128 EmulationWhen enabled, GS1 DataBar™ Expanded barcodes will be
GS1 DataBar™ Expanded Enter/Exit Programming ModeProduct Reference Guide 153GS1 DataBar™ Expanded Length ControlThis featur
Enter/Exit Programming Mode GS1 DataBar™ Expanded154WDI4600GS1 DataBar™ Expanded Set Length 1This feature specifies one of the barcode lengths for GS1
GS1 DataBar™ Expanded Enter/Exit Programming ModeProduct Reference Guide 155GS1 DataBar™ Expanded Set Length 2This feature
Enter/Exit Programming Mode GS1 DataBar™ Limited156WDI4600GS1 DATABAR™ LIMITEDThe following options apply to the GS1 DataBar™ Limited (formerly RSS Li
Code 93 Enter/Exit Programming ModeProduct Reference Guide 157GS1 DataBar™ Limited 2D ComponentThis feature enables/disable
Enter/Exit Programming Mode Code 93158WDI4600Code 93 Check Character CalculationEnables/disables calculation and verification of an optional Code 93 c
Code 93 Enter/Exit Programming ModeProduct Reference Guide 159Code 93 Length ControlThis feature specifies either variable
Installing the Interface Cable SetupProduct Reference Guide 7Keyboard Wedge ConnectionThe Keyboard Wedge cable has a ‘Y’ co
Enter/Exit Programming Mode Code 93160WDI4600Code 93 Set Length 1Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the mini
Code 93 Enter/Exit Programming ModeProduct Reference Guide 161Code 93 Set Length 2This feature specifies one of the barcode
Enter/Exit Programming Mode MSI162WDI4600Code 93 Quiet ZonesEnables/disables quiet zones for Code 93.$CC9LO02(CR)Code 93 Quiet Zones = Quiet Zones on
MSI Enter/Exit Programming ModeProduct Reference Guide 163MSI Check Character CalculationEnables/Disables calculation and v
Enter/Exit Programming Mode MSI164WDI4600MSI Length ControlThis feature specifies either variable length decoding or fixed length decoding for the MSI
MSI Enter/Exit Programming ModeProduct Reference Guide 165MSI Set Length 1This feature specifies one of the barcode lengths
Enter/Exit Programming Mode MSI166WDI4600MSI Set Length 2This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the max
Plessey Enter/Exit Programming ModeProduct Reference Guide 167PLESSEYThe following options apply to the Plessey symbology.P
Enter/Exit Programming Mode Plessey168WDI4600Plessey Check Character TransmissionEnables/disables transmission of an MSI check character.$CPLCT00(CR)P
Plessey Enter/Exit Programming ModeProduct Reference Guide 169Plessey Set Length 1This feature specifies one of the barcode
Setup Interface Selection8WDI4600Figure 5. Other Interface ConnectionsIBM Keyboard Wedge or...Specific cables are required for connection to different
Enter/Exit Programming Mode Plessey170WDI4600Plessey Set Length 2This feature specifies one of the barcode lengths for Plessey Length Control. Length
Product Reference Guide1712D SYMBOLOGIES 2D Global Features• 2D Maximum Decoding Time, page 172• 2D Normal/Inverse Symbol Control, page 173• 2D Struct
Enter/Exit Programming Mode 2D Global Features172WDI46002D Maximum Decoding TimeThis feature specifies the maximum amount of time the software will sp
2D Global Features Enter/Exit Programming ModeProduct Reference Guide 1732D Structured AppendEnables/disables ability of re
Enter/Exit Programming Mode Aztec Code174WDI4600Aztec CodeAztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code
Aztec Code Enter/Exit Programming ModeProduct Reference Guide 175Aztec Code Set Length 1Specifies one of the barcode length
Enter/Exit Programming Mode Aztec Code176WDI4600Aztec Code Set Length 2This feature specifies one of the barcode lengths for Aztec Code Length Control
China Sensible Code Enter/Exit Programming ModeProduct Reference Guide 177China Sensible CodeChina Sensible Code Enable / D
Enter/Exit Programming Mode China Sensible Code178WDI4600China Sensible Code Set Length 1Specifies one of the barcode lengths for China Sensible Code
China Sensible Code Enter/Exit Programming ModeProduct Reference Guide 179China Sensible Code Set Length 2This feature spec
Interface Selection SetupProduct Reference Guide 9Table 1. Available InterfacesRS-232 FEATURESRS-232 standard interface
Enter/Exit Programming Mode Data Matrix180WDI4600Data MatrixData Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labe
Data Matrix Enter/Exit Programming ModeProduct Reference Guide 181Data Matrix Length ControlThis feature specifies either v
Enter/Exit Programming Mode Data Matrix182WDI4600Data Matrix Set Length 2This feature specifies one of the barcode lengths for Data Matrix Length Cont
Maxicode Enter/Exit Programming ModeProduct Reference Guide 183MaxicodeMaxicode Enable / Disable Enables/disables ability o
Enter/Exit Programming Mode Maxicode184WDI4600Maxicode Length ControlThis feature specifies either variable length decoding or fixed length decoding f
Maxicode Enter/Exit Programming ModeProduct Reference Guide 185Maxicode Set Length 2This feature specifies one of the barco
Enter/Exit Programming Mode PDF417186WDI4600PDF417PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels.$CP4EN00(
PDF417 Enter/Exit Programming ModeProduct Reference Guide 187PDF417 Set Length 1Specifies one of the barcode lengths for PD
Enter/Exit Programming Mode PDF417188WDI4600PDF417 Set Length 2This feature specifies one of the barcode lengths for PDF417 Length Control. Length 2 i
Micro PDF417 Enter/Exit Programming ModeProduct Reference Guide 189Micro PDF417Micro PDF417 Enable / Disable Enables/disabl
Wasp Barcode Technologies1400 10th StreetPlano, Texas USA 75074Tel. 214-547-4100Tel. 214-547-4101©2000-2013 Wasp Barcode Technologies, Inc. (an unpub
KEYBOARD FEATURES
Enter/Exit Programming Mode Micro PDF417190WDI4600Micro PDF417 Length ControlThis feature specifies either variable length decoding or fixed length de
Micro PDF417 Enter/Exit Programming ModeProduct Reference Guide 191Micro PDF417 Set Length 2This feature specifies one of t
Enter/Exit Programming Mode QR Code192WDI4600QR CodeQR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels$CQREN
QR Code Enter/Exit Programming ModeProduct Reference Guide 193QR Code Set Length 1Specifies one of the barcode lengths for
Enter/Exit Programming Mode QR Code194WDI4600QR Code Set Length 2This feature specifies one of the barcode lengths for QR Code Length Control. Length
Micro QR Code Enter/Exit Programming ModeProduct Reference Guide 195Micro QR CodeMicro QR Code Enable/DisableEnables/disabl
Enter/Exit Programming Mode Micro QR Code196WDI4600Micro QR Code Set Length 1Specifies one of the barcode lengths for Micro QR Code Length Control. Le
Micro QR Code Enter/Exit Programming ModeProduct Reference Guide 197Micro QR Code Set Length 2This feature specifies one of
Enter/Exit Programming Mode UCC Composite198WDI4600UCC CompositeUCC Composite Enable / Disable Enables/disables the ability of the reader to decode th
UCC CompositeProduct Reference Guide 199UCC Optional Composite Timer Specifies the amount of time the system will wait for
KEYBOARD (continued) FEATURESKeyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only key-board
Postal Code Selection200WDI4600Postal Code SelectionEnables/disables the ability of the scanner to decode labels of a specific postal symbology.• Disa
Postal Code SelectionProduct Reference Guide 201Postal Code Selection (continued)$CPOEN06(CR)Postal Code Selection = Enable
Postal Code Selection202WDI4600NOTES
Product Reference Guide203 MOTION FEATURESMOTION AIMING CONTROL on page 203MOTION SENSITIVITY on page 204MOTIONLESS TIMEOUT on page 204Use this chapte
Enter/Exit Programming Mode Motion Features204WDI4600Motion SensitivityDefines discrete set of levels for scanner motion sensitivity when in handheld
Product Reference Guide205Chapter 4ReferencesThis section contains explanations and examples of selected barcode features. See "Configuration Us
References206WDI4600RS-232 ParametersRS-232 Baud RateBaud rate is the number of bits of data transmitted per second. Set the reader's baud rate t
RS-232 ParametersProduct Reference Guide 207RS-232/USB COM ParametersIntercharacter DelayThis parameter specifies the inter
References208WDI4600ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader
RS-232 ParametersProduct Reference Guide 209NAK CharacterThis setting specifies an ASCII character or hex value to be used
Setup Customizing Configuration Settings12WDI4600Customizing Configuration SettingsConfigure Interface SettingsIf after scanning the interface barcode
References210WDI4600ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK character from the host following label
RS-232 ParametersProduct Reference Guide 211ACK NAK Retry CountThis feature specifies the number of times the reader retrie
References212WDI4600Disable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII characters or any hex value from
RS-232 ParametersProduct Reference Guide 213Enable CharacterSpecifies the value of the RS-232 host command used to enable t
References214WDI4600Keyboard InterfaceWedge Quiet IntervalSpecifies the amount of time the reader looks for keyboard activity before it breaks the key
Keyboard InterfaceProduct Reference Guide 215Intercharacter DelayThis parameter specifies the intercharacter delay between
References216WDI4600Intercode DelaySpecifies the delay between labels transmitted to the host for this interface. The selectable range for this featur
SymbologiesProduct Reference Guide 217SymbologiesSet LengthLength Control allows you to select either variable length decod
References218WDI46004. Scan the appropriate two digits from the keypad in Appendix D, Keypad that represent the length setting which was determined in
Data EditingProduct Reference Guide 219Please Keep In Mind...• Modifying a message string is not a mandatory requirement. D
Customizing Configuration Settings SetupProduct Reference Guide 13Resetting the Product Configuration to DefaultsRestore Cu
References220WDI4600Global AIM IDThis feature enables/disables addition of AIM IDs for all symbology types.AIM label identifiers (as opposed to custom
Data EditingProduct Reference Guide 221Label IDA Label ID is a customizable code of up to three ASCII characters (each can
References222WDI4600DATABAR 14 COMPOSITER4 523400 c 523400DATABAR EXPANDEDRX 525800 t 740000DATABAR EXPANDED COMPOSITERX 525800 d 525800DATABAR LIMITE
Data EditingProduct Reference Guide 223MSI@ 400000 Z 5A0000PDF417P 500000 r 720000PLESSEYa 610000 a 610000POSTAL AUSTRALIAN
References224WDI4600Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a single symbology:1. Go to page 49 and scan the
Data EditingProduct Reference Guide 225Table 36STEP ACTION EXAMPLES1. Scan the ENTER/EXIT barcode(Scanner enters Programmin
References226WDI4600Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in
Reading ParametersProduct Reference Guide 227Reading ParametersGood Read LED DurationThis feature specifies the amount of t
References228WDI4600Scanning FeaturesScan ModeThis mode is associated with typical handheld reader operation. Selects the scan operating mode for the
Scanning FeaturesProduct Reference Guide 229Stand Mode Off TimeThis feature specifies the amount of time reader illuminatio
Setup Customizing Configuration Settings14WDI4600NOTES
References230WDI4600Scanning Active TimeThis setting specifies the amount of time that the reader stays in scan ON state once the state is entered. Th
Scanning FeaturesProduct Reference Guide 231Aiming Duration TimeSpecifies the frame of time the aiming pointer remains on a
References232WDI4600Flash On TimeThis feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 mi
Scanning FeaturesProduct Reference Guide 233Flash Off TimeThis feature specifies the OFF time for the indicator LED while i
References234WDI4600Multiple Labels Ordering by Code SymbologyThis feature Specifies the transmission ordering by symbology type, when Multiple Labels
Scanning FeaturesProduct Reference Guide 235Table 44HexValue Symbology IDHexValue Symbology ID00Don't care2CGTIN501UPC
References236WDI4600Motion FeaturesMotionless TimeoutThis setting specifies the amount of time that the reader takes to assume that it is in a motionl
Product Reference Guide237Appendix ATechnical SpecificationsTable 46 contains Physical and Performance Characteristics, User Environment and Regulator
Technical Specifications238WDI4600Depth of Field (Typical) a Symbology Standard Range (SR) ModelsCode 395mil: 1.6” -7.5” (4.0 -19cm) 10mil: 0.4” - 11.
Technical SpecificationsProduct Reference Guide 239Decode Capability1D BarcodesUPC/EAN/JAN (A, E, 13, 8); UPC/EAN/JAN (incl
Product Reference Guide15Chapter 3Configuration Using BarcodesThis and following sections provide programming barcodes to configure your reader by cha
Item DescriptionUser Environment WDI4600Operating Temperature32° to 131° F (0° to 55° C)Charging TemperatureN/AStorage Temperature-4° to 158° F (-20°
Technical SpecificationsProduct Reference Guide 241Imager LabelingSample labels are shown for illustrative purposes only. P
Technical Specifications242WDI4600Standard Cable PinoutsFigure 10, and Table 47 provide standard pinout information for the interface cable.Figure 10
Technical SpecificationsProduct Reference Guide 243LED and Beeper IndicationsThe reader’s beeper sounds and its LED illumin
Technical Specifications244WDI4600Table 49Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.Label Program
Product Reference Guide245Appendix BStandard DefaultsThe most common configuration settings are listed in the “Default” column of the table below. Pag
Standard Defaults246WDI4600Disable Character‘D’ 30Enable Character‘E’ 30KEYBOARD WEDGECountry ModeU.S. Keyboard 32Send Control Characters00 36Wedge Qu
Standard DefaultsProduct Reference Guide 247Good Read Beep Length80 ms 62Good Read Beep VolumeHigh 63Good Read LED Duration
Standard Defaults248WDI4600CODE SELECTION - 1D SYMBOLOGIESCode EAN/UPCCoupon ControlEnable only UPCAcoupon decoding81UPC-AUPC-A Enable/DisableEnable 8
Standard DefaultsProduct Reference Guide 249EAN 8 Check Character TransmissionSend91Expand EAN 8 to EAN 13Disable92EAN 8 2D
Enter/Exit Programming Mode16WDI4600To program features:1. Scan the ENTER/EXIT PROGRAMMING barcode, available at the top of each pro-gramming page, wh
Standard Defaults250WDI4600Code 39 Danish PPT Enable/DisableDisable 110Code 39 LaPoste Enable/DisableDisable 111Code 39 PZN Enable/DisableDisable 111C
Standard DefaultsProduct Reference Guide 251Interleaved 2 of 5 CIP HR Enable/DisableDisable 127Follett 2 of 5Follett 2 of 5
Standard Defaults252WDI4600Codabar Set Length 250 142ABC CodabarDisable 143ABC CodabarABC Codabar Enable/DisableDisable 143ABC Codabar Concatenation M
Standard DefaultsProduct Reference Guide 253GS1 DataBar™ Limited 2D Component2D component not required157Code 93Code 93 Ena
Standard Defaults254WDI4600Aztec Code Length ControlVariable 174Aztec Code Set Length 11 175China Sensible Code Enable / DisableDisable 177China Sensi
Standard DefaultsProduct Reference Guide 255Micro QR Code Enable/DisableDisable 195Micro QR Code Length ControlVariable 195
Standard Defaults256WDI4600NOTES
Product Reference Guide257Appendix CSample BarcodesThe sample barcodes in this appendix are typical representations for their symbology types.1D Barco
Sample Barcodes258WDI4600Sample Barcodes (continued) Code 32Codabar13579 Code 93 Code 11123456789
Sample BarcodesProduct Reference Guide 259GS1 DataBar™ (RSS)GS1 DataBar™ Expanded Stacked1029384756019283746501928374602947
Global Interface Features Enter/Exit Programming ModeProduct Reference Guide 17GLOBAL INTERFACE FEATURESThe following inter
Sample Barcodes260WDI46002D BarcodesAztec DatamatrixChina Sensible Code MaxiCodePDF 417ABCabcMicro PDF 417
Product Reference Guide261Appendix DKeypadUse the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.01234
Keypad262WDI4600ABCDEF
Product Reference Guide263Appendix EScancode TablesControl Character EmulationControl character emulation selects from different scancode tables as li
264WDI4600Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLETable 51. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x3 x4 x
Product Reference Guide 265Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE (continued)Table 52. Scancode Set When Control Character
266WDI4600Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 53. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x3 x4 x5 X6 x
Product Reference Guide 267Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode (continued)Table 54. Scancode Set When Control Character is 02
268WDI4600Digital InterfaceTable 55. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC+@SOHC(S)
Product Reference Guide 269IBM31xx 102-keyTable 57. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
Enter/Exit Programming Mode Global Interface Features18WDI4600NOTES
270WDI4600IBM XTTable 59. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC+@SOHC(S)+ASTXC(S)+
Scancode TablesProduct Reference Guide 271Microsoft Windows Codepage 1252Windows-1252 is a character encoding of the Latin
Scancode Tables272WDI4600NOTES
ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE
Wasp Barcode Technologies1400 10th StreetPlano, Texas USA 75074www.waspbarcode.com820033790 (Rev. C) December 2013
Product Reference Guide19RS-232 INTERFACEBAUD RATE on page 20DATA BITS on page 21STOP BITS on page 21PARITY on page 22HANDSHAKING CONTROL on page 23Us
Product Reference GuideiTable of ContentsINTRODUCTION ...
Enter/Exit Programming Mode RS-232 Interface20WDI4600Baud RateSee page 206 for information on this feature.$CR2BA00(CR)Baud Rate = 1200$CR2BA01(CR)Bau
RS-232 Interface Enter/Exit Programming ModeProduct Reference Guide 21Data BitsThis parameter allows the reader to interfac
Enter/Exit Programming Mode RS-232 Interface22WDI4600ParityThis feature specifies parity required for sending and receiving data. Select the parity ty
RS-232 Interface Enter/Exit Programming ModeProduct Reference Guide 23Handshaking ControlDEFAULT$CR2HC00(CR)Handshaking Con
Product Reference Guide24RS-232/USB-COM INTERFACESINTERCHARACTER DELAY on page 25BEEP ON ASCII BEL on page 25BEEP ON NOT ON FILE on page 26ACK NAK OPT
RS-232/USB-Com Interfaces Enter/Exit Programming ModeProduct Reference Guide 25Intercharacter DelayThis parameter specifies
Enter/Exit Programming Mode RS-232/USB-Com Interfaces26WDI4600Beep On Not on FileThis option enables/disables the action of the reader to sound a thre
RS-232/USB-Com Interfaces Enter/Exit Programming ModeProduct Reference Guide 27ACK CharacterThis setting specifies an ASCII
Enter/Exit Programming Mode RS-232/USB-Com Interfaces28WDI4600ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an AC
RS-232/USB-Com Interfaces Enter/Exit Programming ModeProduct Reference Guide 29ACK NAK Error HandlingThis feature specifies
iiWDI4600USB Keyboard Speed ...
Enter/Exit Programming Mode RS-232/USB-Com Interfaces30WDI4600Disable CharacterSpecifies the value of the RS-232 host command used to disable the read
Product Reference Guide31KEYBOARD SETTINGSCOUNTRY MODE on page 32SEND CONTROL CHARACTERS on page 36WEDGE QUIET INTERVAL on page 37INTERCODE DELAY on p
Enter/Exit Programming Mode Keyboard Settings32WDI4600Country ModeThis feature specifies the country/language supported by the keyboard. Several langu
Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 33Country Mode (continued)$CKBCO04(CR)Country Mode = F
Enter/Exit Programming Mode Keyboard Settings34WDI4600Country Mode (continued)$CKBCO14(CR)Country Mode = LithuanianSupports only the interfaces listed
Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 35Country Mode (continued)$CKBCO09(CR)Country Mode = S
Enter/Exit Programming Mode Keyboard Settings36WDI4600Send Control CharactersThis feature specifies how the reader transmits ASCII control characters
Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 37Wedge Quiet IntervalSpecifies amount of time to look
Enter/Exit Programming Mode Keyboard Settings38WDI4600Caps Lock StateThis option specifies the format in which the reader sends character data. This d
Keyboard Settings Enter/Exit Programming ModeProduct Reference Guide 39USB Keyboard SpeedThis option specifies the USB poll
Product Reference GuideiiiUPC-A 2D Component ...
$CKBSP07(CR)USB Keyboard Speed = 7ms$CKBSP08(CR)USB Keyboard Speed = 8ms$CKBSP09(CR)USB Keyboard Speed = 9ms$CKBSP0A(CR)USB Keyboard Speed = 10msEnter
Product Reference Guide41USB-OEM INTERFACEUSB-OEM DEVICE USAGE on page 42INTERFACE OPTIONS on page 42Feature settings for USB interfaces differ depend
Enter/Exit Programming Mode USB-OEM Interface42WDI4600USB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of two di
Product Reference Guide43DATA FORMATGLOBAL PREFIX/SUFFIX starting on page 44GLOBAL AIM ID starting on page 45LABEL ID starting on page 48•Label ID: Pr
Enter/Exit Programming Mode Data Format44WDI4600Global Prefix/SuffixThis option sets up to 20 characters each from the set of ASCII characters or any
Data Format Enter/Exit Programming ModeProduct Reference Guide 45Global AIM IDThis feature enables/disables addition of AIM
Enter/Exit Programming Mode Data Format46WDI4600DATABAR EXPANDED COMPOSITE e 65DATABAR LIMITED e 65DATABAR LIMITED COMPOSITE e 65DATA MATRIX d 64EAN12
Data Format Enter/Exit Programming ModeProduct Reference Guide 47Set AIM ID Individually for GS1-128This feature configures
Enter/Exit Programming Mode Data Format48WDI4600Label IDA Label ID is a customizable code of up to three ASCII characters (convert to Hex using the AS
Data Format Enter/Exit Programming ModeProduct Reference Guide 49Individually Set Label IDThis feature configures a Label I
ivWDI4600Code 128 Set Length 1 ...
Enter/Exit Programming Mode Data Format50WDI4600Label ID Symbology Selection − 1D Symbologies This option selects the symbology for which a Label ID i
Data Format Enter/Exit Programming ModeProduct Reference Guide 51Label ID Symbology Selection − 1D Symbologies (continued)$
Enter/Exit Programming Mode Data Format52WDI4600Label ID Symbology Selection − 1D Symbologies (continued)$CXBIDSet GS1 DataBar Expanded Label ID Chara
Data Format Enter/Exit Programming ModeProduct Reference Guide 53Label ID Symbology Selection − 1D Symbologies (continued)$
$CAZIDSet Aztec Label ID Character(s)$CMXIDSet Maxicode Label ID Character(s)$CCSIDSet China Sensible Label ID Character(s)$CP4IDSet PDF 417 Label ID
Data Format Enter/Exit Programming ModeProduct Reference Guide 55Advanced Formatting: User Label EditAdvanced formatting is
Enter/Exit Programming Mode Data Format56WDI4600Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 ch
Product Reference Guide57 READING PARAMETERS DOUBLE READ TIMEOUT starting on page 58LED AND BEEPER INDICATORS starting on page 60•Power On Alert•Good
Enter/Exit Programming Mode Reading Parameters58WDI4600Double Read TimeoutDouble Read Timeout prevents a double read of the same label by setting the
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 59Double Read Timeout (continued)$CSNDR50(CR)Double R
Product Reference GuidevGS1 DataBar™ Omnidirectional Enable/Disable ...
Enter/Exit Programming Mode Reading Parameters60WDI4600LED AND BEEPER INDICATORSPower On AlertDisables or enables the indication (from the Beeper) tha
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 61Good Read Beep TypeSpecifies whether the good read
Enter/Exit Programming Mode Reading Parameters62WDI4600Good Read Beep Length
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 63Good Read Beep VolumeSelects the beeper volume (lou
Enter/Exit Programming Mode Reading Parameters64WDI4600Good Read LED DurationThis feature specifies the amount of time that the Good Read LED remains
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 65SCANNING FEATURESScan ModeSelects the reader’s scan
Enter/Exit Programming Mode Reading Parameters66WDI4600Stand Mode IndicationThis operation is useful for indicating when the reader is in Stand Mode.
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 67Stand OperationSpecifies the behavior of the reader
Enter/Exit Programming Mode Reading Parameters68WDI4600Pick ModeSpecifies the ability of the reader to decode labels only when they are close to the c
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 69Stand Mode Illumination Off TimeSpecifies the amoun
viWDI4600Maxicode Set Length 2 ...
Enter/Exit Programming Mode Reading Parameters70WDI4600Stand Illumination ControlControls the illumination status while the reading mode is stand mode
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 71Flash On TimeThis feature specifies the ON time for
Enter/Exit Programming Mode Reading Parameters72WDI4600Aiming PointerEnables/disables the aiming pointer for all symbologies.$CTAAP00(CR)Aiming Pointe
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 73Green Spot DurationSpecifies the duration of the go
Enter/Exit Programming Mode Reading Parameters74WDI4600Partial Label Reading ControlEnable/Disable to ignore partial labels to be read within the boun
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 75CORDED ONLY FEATURESCorded Stand ModeSets the Stan
Enter/Exit Programming Mode Reading Parameters76WDI4600Corded Stand BeepEnables/Disables the beep that indicates when Corded Stand position is detecte
Reading Parameters Enter/Exit Programming ModeProduct Reference Guide 77 MULTIPLE LABEL READINGIn standard (default) mode,
Enter/Exit Programming Mode Reading Parameters78WDI4600Multiple Labels Ordering by Code SymbologyThis feature allows you to specify the order multiple
Product Reference Guide791D SYMBOLOGIES1D Code SelectionThe reader supports the following 1D symbologies (barcode types). See "2D Symbologies&quo
Product Reference GuideviiLED and Beeper Indications ...
Enter/Exit Programming Mode Disable All Symbologies80WDI46004. Complete the programming sequence by scanning the ENTER/EXIT PROGRAM-MING barcode to ex
Code EAN/UPC Enter/Exit Programming ModeProduct Reference Guide 81CODE EAN/UPCCoupon ControlThis feature is used to control
Enter/Exit Programming Mode Code EAN/UPC82WDI4600UPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled, the reader
Code EAN/UPC Enter/Exit Programming ModeProduct Reference Guide 83Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 da
Enter/Exit Programming Mode UPC-E84WDI4600UPC-A 2D ComponentThis feature enables/disables a requirement that a 2D label component be decoded when a ba
UPC-E Enter/Exit Programming ModeProduct Reference Guide 85UPC-E Check Character TransmissionEnable this option to transmit
Enter/Exit Programming Mode UPC-E86WDI4600Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the
GTIN Formatting Enter/Exit Programming ModeProduct Reference Guide 87UPC-E Number System Character TransmissionThis feature
Enter/Exit Programming Mode EAN 13 (Jan 13)88WDI4600EAN 13 (JAN 13)The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable/DisableW
EAN 13 (Jan 13) Enter/Exit Programming ModeProduct Reference Guide 89EAN-13 Flag 1 CharacterEnables/disables transmission o
Commentaires sur ces manuels