Enter/Exit Programming Mode RS-232/USB-Com Interfaces
28
WDI4600
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout.
See page 210 for more information on setting th
is feature.
$CR2AT
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE barcode above, then the
barcode at left followed by the digits from the
Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). End by
scanning the ENTER/EXIT
barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not sav
e the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and
a selection of 255 specifies unlimited retries. See page 211 for more information.
$CR2AR
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE barcode above, then the
barcode at left followed by the digits from the
Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). End by
scanning the ENTER/EXIT
barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not sav
e the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
003 = 3 Retries