Code 11 ENTER/EXIT PROGRAMMING MODE
186
WLS9600
Code 11 Set Length 2
This feature specifies one of the barcode lengths for Code 11 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies
to ignore this length (only
one fixed length).
Table 19 provides examples for setting Length 2. See page 243 for detailed instructions on
setting this feature.
Table 19. Code 11 Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (pad with
leading ze
roes)
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 11 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘0’ and ‘F’ ‘3’ AND 2’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 11 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not
sav
e the entry string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters